Jul,11

IEC 60317-23 pdf download

IEC 60317-23 pdf download

IEC 60317-23 pdf download.Specifications for particular types of winding wires
1 Scope
This International Standard specifies the requirements of solderable enamelled round copper winding wire of class 180 with a sole coating based on polyesterimide resin, which may be modified providing it retains the chemical identity of the original resin and meet all specified wire requirements. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. Class 180 is a thermal class that requires a minimum temperature index of 180 and a heat shock temperature of at least 200 °C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor diameters covered by this standard is: – Grade 1: 0,020 mm up to and including 1,600 mm; – Grade 2: 0,020 mm up to and including 1,600 mm. The nominal conductor diameters are specified in clause 4 of IEC 60317-0-1.
2 Normative references
The following normative documents contain provisions which, through reference in this text, constitute provisions of this International Standard. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. However, parties to agreements based on this International Standard are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies. Members of IEC and ISO maintain registers of currently valid International Standards. IEC 60317-0-1:1990, Specifications for particular types of winding wires – Part 0: General requirements – Section 1: Enamelled round copper wire.
4 Dimensions
See clause 4 of IEC 60317-0-1.
5 Electrical resistance
See clause 5 of IEC 60317-0-1.
6 Elongation
See clause 6 of IEC 60317-0-1.
7 Springiness
See clause 7 of IEC 60317-0-1.
8 Flexibility and adherence
See clause 8 of IEC 60317-0-1, where the constant K used for the calculation of the number of revolutions for the peel test shall be 110 mm.
9 Heat shock
See clause 9 of IEC 60317-0-1, where the minimum heat shock temperature shall be 200 °C.
10 Cut-through
No failure shall occur within 2 min at 265 °C.
11 Resistance to abrasion (nominal conductor diameters from 0,250 mm up to and including 1,600 mm)
The wire shall meet the requirements given in table 1.